GS716Tv2 and GS724Tv3 Software Administration Manual
The following table describes the EAP statistics displayed on the screen.
Field | Description |
Ports | Specifies the interface which is polled for statistics. |
|
|
Frames Received | Displays the number of valid EAPOL frames received on the port. |
|
|
Frames Transmitted | Displays the number of EAPOL frames transmitted through the port. |
|
|
Start Frames Received | Displays the number of EAPOL Start frames received on the port. |
|
|
Logoff Frames Received | Displays the number of EAPOL Log off frames that have been received on |
| the port. |
|
|
Last Frame Version | Displays the protocol version number attached to the most recently |
| received EAPOL frame. |
|
|
Last Frame Source | Displays the source MAC Address attached to the most recently received |
| EAPOL frame. |
|
|
Invalid Frames Received | Displays the number of unrecognized EAPOL frames received on this |
| port. |
|
|
Length Error Frames Received | Displays the number of EAPOL frames with an invalid Packet Body |
| Length received on this port. |
|
|
Response/ID Frames Received | Displays the number of EAP Respond ID frames that have been received |
| on the port. |
|
|
Response Frames Received | Displays the number of valid EAP Response frames received on the port. |
|
|
Request/ID Frames | Displays the number of EAP Requested ID frames transmitted through the |
Transmitted | port. |
|
|
Request Frames Transmitted | Displays the number of EAP Request frames transmitted through the port. |
|
|
Use the buttons at the bottom of the page to perform the following actions:
•To clear all the EAP counters for all ports on the switch, select the check box in the row heading and click Clear. The button resets all statistics for all ports to default values.
•To clear the counters for a specific port, select the check box associated with the port and click Clear.
•Click Refresh to refresh the data on the screen and display the most current statistics.
212 Chapter 6: Monitoring the System