Chapter 7 Menu Operations — Menu list

Item

 

Description of settings

Remark

[AWB AREA]

Switches the detection area that automatically adjusts white balance.

 

 

 

 

[25%]

Detects 25% of the area near screen center.

 

 

 

 

[50%]

Detects 50% of the area near screen center.

 

 

 

 

[90%]

Detects 90% of the screen area.

 

 

 

[AWB B]

Sets the function assigned to the <WHITE BAL> switch <B>.

 

 

 

 

[MEM]

Records setting values when white balance is automatically

 

 

 

 

 

adjusted, and operates using those values each time the

 

 

 

 

 

<WHITE BAL> switch is moved to <B>.

 

 

 

 

[ATW]

Assigns the auto tracking white balance function.

 

 

 

[ATW SPEED]

Switches the control speed of auto tracking white balance function.

 

 

 

 

[NORMAL], [SLOW], [FAST]

 

 

 

[TEMP PRE SEL SW]

Selects whether to set the preset color temperature to be variable or to switch

 

 

 

 

between [3200K]/[5600K]. Right after the value is changed, the preset color

 

 

 

 

temperature is set to [3200K] (when the filter <A> is set).

 

 

 

 

[VAR]

Switchable from [< 2300K] to [> 15000K].

 

 

 

 

[3.2K/5.6K]

Can be switched to [3200K] or [5600K].

 

 

 

[COLOR TEMP PRE]

Sets color temperature when the <WHITE BAL> switch is in the <PRST> position.

ffThe range of color temperature that can be set

 

Sets the preset color temperatures selected in [TEMP PRE SEL SW].

differs depending on the position of the <CC

 

When [VAR] is selected for [TEMP PRE SEL SW]:

FILTER> dial. When a high color temperature is

 

[< 2300K]…[3200K]…[> 15000K]

set, sometimes the value does not change even if

 

When [3.2K/5.6K]is selected for [TEMP PRE SEL SW]:[3200K], [5600K]

the color temperature is changed.

[AWB A TEMP]

Sets color temperature when the <WHITE BAL> switch is in the <A> position.

 

 

 

 

If the white balance is automatically adjusted in the <A> position, the color

 

 

 

 

temperature at that time is recorded to the <WHITE BAL> switch <A> position.

 

 

 

 

[< 2300K]…[3200K]…[> 15000K]

 

 

 

[AWB B TEMP]

Sets color temperature when the <WHITE BAL> switch is in the <B> position.

 

 

 

 

If the white balance is automatically adjusted in the <B> position, the color

 

 

 

 

temperature at that time is recorded to the <WHITE BAL> switch <B> position.

 

 

 

 

[< 2300K]…[3200K]…[> 15000K]

 

 

 

 

 

 

 

 

are factory settings.

 

 

 

 

 

 

[USER SW GAIN]

 

 

 

 

 

 

 

 

 

Item

 

Description of settings

Remark

[S.GAIN]

Selects the gain to enable to the <SUPER GAIN> switch (<USER> button).

ffSet to be valid/invalid per gain value. All gain

 

[30dB], [36dB], [42dB]

values are valid in the factory settings.

[DS.GAIN]

Selects the accumulated gain to enable to the <DS.GAIN> switch (<USER>

ffSet to be valid/invalid per gain value. The gain

 

button).

 

value of [20dB] or lower is valid in the factory

 

[6dB], [10dB], [12dB], [15dB], [20dB], [24dB], [28dB], [34dB]

setting.

 

 

 

ffWhen [DS.GAIN] function is operating, the shutter

 

 

 

mode is [OFF].

 

 

 

 

 

are factory settings.

 

 

 

 

 

 

[LENS/IRIS]

 

 

 

 

 

 

 

 

 

Item

 

Description of settings

Remark

[A.IRIS LEVEL]

Sets the auto iris target value.

 

 

 

 

[0]…[50]…[100]

 

 

 

 

[A.IRIS PEAK/AVE]

Sets the ratio included in the peak for auto iris standard.

 

 

 

 

Larger ratios correspond to a peak within the IRIS detection window, and smaller

 

 

 

 

ones correspond to average values within the IRIS detection window.

 

 

 

 

[0]…[30]…[100]

 

 

 

 

[A.IRIS WINDOW]

Selects the auto iris detection window.

 

 

 

 

[NORM1]

Window that is near screen center.

 

 

 

 

[NORM2]

Window that is near screen bottom.

 

 

 

 

[CENTER]

Window that is a spot in the screen center.

 

 

 

[S.IRIS LEVEL]

Sets the super iris (backlight compensation) target value.

 

 

 

 

[0]…[70]…[100]

 

 

 

 

[IRIS GAIN]

Selects the IRIS GAIN adjustment side.

ffWhen using the lenses with extenders (such as

 

[CAM], [LENS]

 

x2 and x0.8) sold prior to the FUJINON DIGI

 

 

 

POWER types, set to [LENS] with the extender

 

 

 

inserted, and operate IRIS correction control. If

 

 

 

set to [CAM], the IRIS control of the camera will

 

 

 

no longer function correctly.

[IRIS GAIN VALUE]

Selects the [IRIS GAIN] adjustment value.

 

 

 

 

When [CAM] is selected in [IRIS GAIN], this setting is enabled.

 

 

 

 

[1]…[10]…[20]

 

 

 

 

 

 

 

 

 

are factory settings.

– 151 –