| Chapter 4 Adjustments and Settings for |
|
|
|
| [TEMPORARY PAUSE | Displayed when the reference signal is disrupted and recording is suspended during generator lock input, etc. |
| IRREGULAR SIG] |
|
| [EOM] | Displayed when there is no space remaining on the P2 card. |
| [BOS] | Displayed when the playback position is at the beginning of all clips. |
| [EOS] | Displayed when the playback position is at the end of all clips. |
| [CANNOT REC] | Displayed when recording to the P2 card is not possible, for example, immediately after power is turned on or the P2 card is |
| inserted. Detailed information of the P2 card can be checked in the mode check [FUNCTION] screen. For details, refer to “Mode | |
|
| check display” (page 77). |
| [CANNOT PLAY] | Displayed when playback is not possible, for example, when there are no clips on the P2 card or the P2 card is not inserted. |
| [TEXT MEMO] | Displayed when a text memo is recorded. |
| [TEXT MEMO INVALID] | Displayed when a text memo could not be recorded. |
| [MARK ON/OFF] | Displayed when shot marks are added or deleted. For details on shot marks, refer to “Shot mark recording function” (page 39). |
| [SHOT MARK INVALID] | Displayed when shot marks cannot be added. |
| [UPDATING] | Displayed when playback operation is not accepted during updating of the clip information for playback. |
| [USB DEVICE] | Displayed when the USB device mode is set. Flashes during migration through modes, and after migration through modes |
| is completed, [CONNECTED] is displayed when communication is possible and [DISCONNECTED] is displayed when | |
|
| communication is not possible. |
| [USB STORAGE] | Displayed when the USB storage mode is set. Flashes during migration through modes, and from then on, [CONNECTED] |
| is displayed when the external hard disk is recognized successfully and [DISCONNECTED] is displayed when it cannot be | |
|
| recognized. |
| [THUMBNAIL OPEN] | Displayed during thumbnail operation. |
| [TC REGEN] | Displayed when the <RET> button on the lens is pressed to regenerate to the time code of the last recorded clip to the P2 card. |
| [SLOT SELECT] | Flashes when the <USER> button assigned with [SLOT SEL] is pressed and while switching processing of the recording slot on |
| the P2 card is being executed. | |
|
| |
| [SLOT SELECT | Displayed when the <USER> button assigned with [SLOT SEL] is pressed and switching processing of the recording slot on the |
| INVALID] | P2 card is not possible. |
For details on warnings, refer to “Warning information display” (page 196).
17 Time code display
[TCG 12:59:59:20] | Displays the time code generator value. |
[TCR 12:59:59:20] | Displays the timecode reader value. |
[VUBG AB CD EF 00] | Displays the user’s bit generator value. |
([UBG AB CD EF 00]) |
|
[VUBR 12 34 56 78] | Indicates the user’s bit reader value. |
([UBR 12 34 56 78]) |
|
[CTL −1:59:59:20] | Displays the CTL counter value. |
18 Audio input line and level meter display
Displays the selected channel and its audio level. |
[F]Displayed when the <AUDIO IN> switch is <FRONT>.
[W]Displayed when the <AUDIO IN> switch is <W.L.>.
[R]Displayed when the <AUDIO IN> switch is <REAR>.
19Iris override display
Displays the compensation level when the iris overwrite is functioning.
[++] | Aperture opens by about 1. |
[+] | Aperture opens by about 0.5. |
[−−] | Aperture closes by about 1. |
[−] | Aperture closes by about 0.5. |
(No display) | Reference state. |
20Super iris display
Displayed when super iris is active.
21Iris, F value
[NC] | Displayed when the lens cable is not connected. |
[OPEN] | Displayed when the lens aperture is open. |
[F1.7] to [F16] | Displays the lens aperture value. |
[CLOSE] | Displayed when the lens aperture is closed. |
ffDisplayed when a lens with an aperture value display function is used. Also, flashes when the iris override is variable.
22Super black display
Displayed when super black is active.
23Zoom display
[Z00] to [Z99] | Displays the zoom amount. Note, however, that this item is not displayed in the case of lenses without a zoom position return | |
even if it is set to be displayed. | ||
| ||
[Z**.*mm] | When a serial lens is connected, the display unit can be changed in the main menu → [VF] → [VF INDICATOR] → [ZOOM/ | |
FOCUS]. | ||
|