Chapter 5 Preparation — Power supply

Power supply

A battery or an external DC power supply can be used as the power supply.

Using batteries

Connection of the following batteries to the camera has been verified.

rr Anton/Bauer batteries

HYTRON140

DIONIC90

rr IDX batteries

ENDURA10

rr PAG batteries

PAG L96e

@@NOTE

tt Other batteries can be supported by changing [BATTERY SELECT] in the main menu [I/F SETUP] [BATTERY/P2CARD]. Use of batteries that are already verified as connectable to the camera is recommended.

tt Before you use a battery, charge it with a battery charger. (For details on charging, refer to each instruction operation.) tt When using the light (Ultralight 2), using a battery of 90 Wh or more is recommended.

tt When using a studio system (AG‑BS300, AG‑CA300G) to turn the light on, attach the battery plate to the AG‑CA300G before attaching the battery. Supply the light power supply from the battery plate. When supplying the light power supply from the light output terminal on the camera, overcurrent when the light is turned on sometimes prevents the camera from starting because of the overcurrent protection of AG‑BS300 and AG‑CA300G.

Mounting and setting battery

Using Anton/Bauer batteries

Release lever

Anton/Bauer batteries

1Mount the Anton/Bauer battery.

2 Insert the battery terminal and slide in the direction of the arrow.

3Set the battery type.

Select the battery in the main menu [I/F SETUP] [BATTERY/P2CARD] [BATTERY SELECT]. For details, refer to “Setting menu basic operations” (page 134).

@@NOTE

tt To remove the battery, keep the release lever of the battery holder completely down, slide the battery in the opposite direction of when you mounted it.

– 94 –