Chapter 10
REMOTE
| 1 | CAM DATA (H) | Data from camera to remote control (H) |
| 2 | CAM DATA (C) | Data from camera to remote control (C) |
| 3 | CAM CONT (H) | Control signal from remote control to camera (H) |
| 4 | CAM CONT (C) | Control signal from remote control to camera (C) |
| 5 | R/C ON | Recognition signal of remote control Low: ON |
| 6 | R/C VIDEO OUT | Video signal output to remote control |
| 7 | R/C VIDEO GND | GND for video signal to remote control |
| 8 | NC | Not used |
| 9 | UNREG+12 V | DC 12 V power supply (AJ‑RC10G: Max. 0.75 A) |
| 10 | GND | GND |
Panasonic Parts No.: K1AY110JA001
Manufacturer Parts No.:
Manufacturer Parts No. of cable connector:
@@NOTE
tt Ensure that the total current from the <DC OUT> terminal, <REMOTE> terminal, <VF> terminal, <LENS> terminal does not exceed 2.5 A.
|
| DC OUT | |
| 1 |
| GND |
| 2 |
| R TALLY (open collector) |
| 3 |
| REC START SW |
| 4 |
| +12 V OUT DC (11 V – 17 V) (max. 1.5 A) |
Panasonic Parts No.: K1AY104J0001
Manufacturer Parts No.:
Manufacturer Parts No. of cable connector:
@@NOTE
tt Ensure that the total current from the <DC OUT> terminal, <REMOTE> terminal, <VF> terminal, <LENS> terminal does not exceed 2.5 A.
VF
| 1 |
| DC 12 V power (AJ‑HVF21KG: approx. 0.35 A) | |
| 2 |
| DC 12 V power | |
| 3 | A9.0V |
| DC 9 V power (not used) |
| 4 |
| Viewfinder PB signal GND | |
| 5 |
| Viewfinder PR signal GND | |
| 6 |
| Viewfinder Y signal output | |
| 7 |
| Viewfinder Y signal GND | |
| 8 |
| Serial data clock pulse signal | |
| 9 |
| Pulse signal for serial/parallel conversion data reading | |
| 10 |
| Serial data signal for serial/parallel conversion | |
| 11 |
| GND | |
| 12 |
| On/off of zebra signal | |
| 13 | PEAKING |
| Peaking control (not used) |
| 14 | SPARE |
| Spare (not used) |
| 15 |
| Viewfinder PR signal output | |
| 16 |
| Viewfinder PB signal output | |
| 17 |
| Marker ON/OFF (not used) | |
| 18 |
| F.AUDIO LEVEL adjustment (not used) | |
| 19 |
| F.AUDIO LEVEL GND (not used) | |
| 20 |
| GND | |
|
|
| Panasonic Parts No.: K1AB120H0001 | |
|
| Manufacturer Parts No.: |
@@NOTE
tt Ensure that the total current from the <DC OUT> terminal, <REMOTE> terminal, <VF> terminal, <LENS> terminal does not exceed 2.5 A.