RIO Remote I/O System User Guide
Solaris troubleshooting
Page 277
Remote Terminal Adaptors (RTAs)
Problem Action required
RTA not recognised by system 1. Check physical connections and power.
See page 161.
2. Run the rioconf ig utility to update RIO
system settings.
See page 51.
RTA not booted by system 1. Check the rio.cf file to make sure the RTA
entry exists and contains the boot field.
See page 164.
2. Delete the rio.cf file and run the rioconfig
utility to recreate the system settings.
See page 164 and page 51 .
RTA8 LED next to port 5 does not light up The host card has already assigned 128 ports, if you
haven’t got 128 ports installed, this means that you
have previously removed one or more RTAs from the
network but not deleted them from the configuration.
RTA16 con LED does not light up You have already installed the maximum number of
RTAs up to 128 ports. This situation may arise if you
have previously removed RTAs from the system but
forgotten to delete them from the configuration using
the rioconfig utility.