Chapter 3 LinePrinter Plus Emulation
LinePrinter Plus P-Series XQ Emulation
Printer
Protocol
(from page 125)
P-Series XQ
Control Code
06
6.0LPI
8.0LPI*
10.3LPI
Define CR
Code
CR = CR* CR = CR + LF
Auto LF
Disable*
Enable
| Define LF |
| Compressed |
| |
| Code |
|
| ||
|
|
|
|
|
|
| LF = CR + LF* |
| char 01 | SOH* |
|
| LF = LF |
| char 03 | ETX |
|
|
|
| char 09 | HT |
|
* = Factory Default
Elong/Alt.
Font
Elng=BS Font=SO* Elng=SO Font=BS
Gothic
Typeface
char 02 STX* char 03 ETX char 09 HT
EVFU Select
Enable*
Disable
Upr. Case
Select
Disable*
Enable
Slew Relative
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can select an alternate line spacing of 6, 8 or 10.3 LPI.
Define CR Code
This option controls the action of the printer when it receives a Carriage Return code (hex 0D) from the host computer. If this feature is enabled, each time the printer receives a Carriage Return, it inserts an additional Line Feed code (hex 0A) into the data stream. Do not use this feature if the host computer sends Line Feeds to the printer.
•CR = CR. Does not insert an extra Line Feed after each Carriage Return.
•CR = CR + LF. Inserts an extra Line Feed after each Carriage Return. The next print position will be print position 1 of the next line.
Auto LF
This option defines the printer action when print data is received past the forms width setting.
•Disable. Discards any data past the forms width.
•Enable. Performs an automatic carriage return and line feed when data is received past the forms width.
136