Chapter 3 Menu Options
Centronics (Parallel)
CENTRONICS (from page 54)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Data Bit 8 |
|
| PI Ignored |
| Data Polarity |
| Resp. |
| |
|
|
|
|
|
|
|
|
|
| Polarity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Enable* |
|
| Enable* |
| Standard* |
| Standard* |
| |
|
| Disable |
|
| Disable |
| Inverted |
| Inverted |
|
Busy On Strobe
Enable* Disable
* = Factory Default
Latch
Data On
Leading*
Trailing
Prime Signal
Enable* Disable
TOF Action
Reset*
Do Nothing
Buffer Size
In K
8*
Data Bit 8
•Enable. Allows access to the extended ASCII character set.
•Disable. The printer interprets bit 8 of each incoming data character as a zero, regardless of its actual setting.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper motion.
•Enable. Ignores the PI signal and treats the data as characters or control codes.
•Disable. Causes the printer to interpret the eight data lines as VFU commands when the PI signal is true.
Data Polarity
The Data Polarity parameter must be set to match the data polarity of your host computer.
•Standard. Does not expect the host computer to invert the data.
•Inverted. Expects the data received on the data lines from the host computer to be inverted. Ones become zeros, and vice versa.
80