Chapter 3 Menu Options

Centronics (Parallel)

CENTRONICS (from page 54)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Bit 8

 

 

PI Ignored

 

Data Polarity

 

Resp.

 

 

 

 

 

 

 

 

 

 

 

Polarity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable*

 

 

Enable*

 

Standard*

 

Standard*

 

 

 

Disable

 

 

Disable

 

Inverted

 

Inverted

 

Busy On Strobe

Enable* Disable

* = Factory Default

Latch

Data On

Leading*

Trailing

Prime Signal

Enable* Disable

TOF Action

Reset*

Do Nothing

Buffer Size

In K

8*

1-16

Data Bit 8

Enable. Allows access to the extended ASCII character set.

Disable. The printer interprets bit 8 of each incoming data character as a zero, regardless of its actual setting.

PI Ignored

The PI (Paper Instruction) signal is used to control vertical paper motion.

Enable. Ignores the PI signal and treats the data as characters or control codes.

Disable. Causes the printer to interpret the eight data lines as VFU commands when the PI signal is true.

Data Polarity

The Data Polarity parameter must be set to match the data polarity of your host computer.

Standard. Does not expect the host computer to invert the data.

Inverted. Expects the data received on the data lines from the host computer to be inverted. Ones become zeros, and vice versa.