LinePrinter Plus P-Series Emulation
Auto LF
This option defines the printer action when print data is received past the forms width setting.
•Disable. Discards any data past the forms width.
•Enable. Performs an automatic carriage return and line feed when data is received past the forms width.
Overstrike
Overstrike determines the action required when a line is printed over a previous line because a carriage return was received without a line feed.
•Enable. Prints the second line on top of the first line.
•Disable. Replaces the characters from the first line with the second line.
Define LF Code
•LF = CR + LF. Forces an automatic carriage return with each line feed command. The next print position is position 1 of the next line.
•LF = LF. Does not perform an automatic carriage return. The next print position will be the current print position of the next line.
Select SFCC
This parameter allows you to select which ASCII codes will function as the Special Function Control Code (SFCC) command delimiter.
•ESC (hex 1B)
•SOH (hex 01)
•ETX (hex 03)
•CIRCUMFLEX (hex
•TILDE (hex
NOTE: SOH, ETX and ESC are
EVFU Select
Controls how the printer handles vertical formatting.
•Enable. The default. Selects
•Disable. Disables all EVFU processing.
133