LinePrinter Plus P-Series Emulation
133
Auto LF
This option defines the printer action when print data is received past the
forms width setting.
Disable. Discards any data past the forms width.
Enable. Performs an automatic carriage return and line feed whe n data is
received past the forms width.
Overstrike
Overstrike determines the action required when a line is printed over a
previous line because a carriage return was received without a line feed.
Enable. Prints the second line on top of the first line.
Disable. Replaces the characters from the first line with the second line.
Define LF Code
LF = CR + LF. Forces an automatic carriage return with each line feed
command. The next print position is position 1 of the next line.
LF = LF. Does not perform an automatic carriage return. The next print
position will be the current print position of the next line.
Select SFCC
This parameter allows you to select which ASCII codes will function as the
Special Function Control Code (SFCC) command delimiter. P-Series codes
can use hex 00 through hex 7F. Options include the following:
ESC (hex 1B)
SOH (hex 01)
ETX (hex 03)
CIRCUMFLEX (hex 5E)—also called caret (^)
TILDE (hex 7E)—(~)
NOTE: SOH, ETX and ESC are non-printables. The characters (^) and (~)
are printable; however, do not use them as printables in the host data
stream if either is chosen as a delimiter, or print errors will occur.
EVFU Select
Controls how the printer handles vertical formatting.
Enable. The default. Selects P-Series compatible Electronic Vertical
Format Unit (EVFU).
Disable. Disables all EVFU processing.