All rights reserved

Saw V1.4.doc

Copyright Siemens AG 2008

Manual SIMOTION Flying

 

 

Section E: Appendix

 

 

Error messages

 

 

 

Flying Saw with SIMOTION

A4027118-A0414

 

 

 

 

ErrorID

Explanation

 

error code

 

 

C061

Automatic Run

 

 

Error when activating gearing of the FlyingSawAxis

 

 

( _enablegearing )

 

 

Details in FS_Var structure under RetDINT_enablegearing_FSA

 

C062

Automatic Run

 

 

Error when de-activating gearing after unsuccessful

 

 

synchronization of the FlyingSawAxis ( _disablegearing )

 

 

Details in FS_Var structure under RetDINT_disablegearing_FSA

 

C063

Automatic Run

 

 

Error when de-activating gearing after unsuccessful

 

 

synchronization of the FlyingSawAxis ( _disablegearing )

 

 

Details in FS_Var structure under FR_disablegearing_FSAFSA

 

C064

Automatic Run

 

 

Error for superimposed positioning of the FlyingSawAxis to create

 

 

"gap" ( _pos )

 

 

Details in FS_Var structure under RetDINT_possuperimp_FSA

 

C065

Automatic Run

 

 

Error for superimposed positioning of the FlyingSawAxis to create

 

 

"gap" ( _pos )

 

 

Details in FS_Var structure under FR_possuperimp_FSA

 

C066

Automatic Run

 

 

Error when positioning the FlyingSawAxis ( _pos )

 

 

Details in FS_Var structure under RetDINT_pos_FSA

 

C067

Automatic Run

 

 

Error when positioning the FlyingSawAxis ( _pos )

 

 

Details in FS_Var structure under FR_pos_FSA

 

 

 

 

C071

Automatic to Disable

 

 

Error when stopping the FlyingSawAxis ( move mit v=0)

 

 

Details in FS_Var structure under RetDINT_stop_FSA

 

C072

Automatic to Disable

 

 

Error when stopping the FlyingSawAxis ( move mit v=0)

 

 

Details in FS_Var structure under FR_stop_FSA

 

 

 

 

C081

Automatic to Starting position

 

 

Error when positioning the FlyingSawAxis ( _pos )

 

 

Details in FS_Var structure under RetDINT_pos_FSA

 

C082

Automatic to Starting position

 

 

Error when positioning the FlyingSawAxis ( _pos )

 

 

Details in FS_Var structure under FR_pos_FSA

V 1.4

Release 06/06/08

104/107

Page 104
Image 104
Siemens A4027118-A0414 user manual Section E Appendix