All rights reserved

Saw V1.4.doc

Copyright Siemens AG 2008

Manual SIMOTION Flying

Section C: Integrating the core “flying saw” functions

Program environment and interfaces

Flying Saw with SIMOTION

 

 

A4027118-A0414

 

 

 

 

 

 

Parameter

Data type

Initial value

Description

 

Input/output parameter (IN/OUT)

 

 

UsersInterface

STRUCT

 

User interface

 

ErrorInterface

STRUCT

 

ErrorID of the technology

 

 

 

 

functions

 

InternalData

STRUCT

 

Internal data of the sequence

 

 

 

 

control

 

SyncPos

STRUCT

 

Data of the synchronous

 

Management

 

 

position management

 

TimeCalc

STRUCT

 

Time calculation data

 

Output parameter (OUT)

 

 

 

Done

BOOL

False

Selected mode has been

 

 

 

 

activated.

 

Busy

BOOL

False

Mode changeover is active.

 

 

 

 

 

 

Error

BOOL

False

Indicates faults/errors within

 

 

 

 

the FBs and at the cross-cutter

 

 

 

 

axes.

 

Cut

BOOL

False

The flying saw moves in

 

 

 

 

synchronism with the material

 

 

 

 

web – cutting can start.

 

EndSyncPos

BOOL

False

Alarm, if the flying saw

 

Reached

 

 

passes/exceeds the upper limit

 

 

 

 

value of the synchronous range

 

 

 

 

when in the automatic mode

 

OnTheSpotCut

BOOL

False

The flying saw is in its starting

 

Possible

 

 

position and an immediate cut

 

 

 

 

is possible

 

OnTheSpotCut

BOOL

False

The immediate cut was carried-

 

Done

 

 

out

 

SyncNotPossible

BOOL

False

The last synchronization

 

 

 

 

operation could not be

 

 

 

 

executed with the secondary

 

 

 

 

conditions/constraints present.

 

ErrorID

WORD

0

Fault code

 

State

INT

0

Actual operating mode

 

 

 

 

 

6.3.3Structure of the global data area of the data unit FS_Var

The interconnection and links with the technology objects required and the physical reference quantities and control information are saved in the user interface of the instance data area.

The parameters saved here are generally not changed during fault-free operation of the “flying saw”.

V 1.4

Release 06/06/08

68/107

Page 68
Image 68
Siemens A4027118-A0414 user manual Structure of the global data area of the data unit FSVar, Output parameter OUT