Siemens A4027118-A0414 Using the restart bit, Error messages, Restart after a new start

Models: A4027118-A0414

1 107
Download 107 pages 57.56 Kb
Page 83
Image 83

All rights reserved

Saw V1.4.doc

Copyright Siemens AG 2008

Manual SIMOTION Flying

Section C: Integrating the core “flying saw” functions

Using the "FB_BGD_TEMPLATE_FlyingSaw()"

Flying Saw with SIMOTION

A4027118-A0414

carried-out and the new state has been reached, this is flagged by a high signal at the done block output. The number of the new state can be read- off at the state output.

The sequences and actions that are executed during the changeover are described in detail in Chapter 10.3.4 of this document.

8.4Using the restart bit

Restart after a new start

The restart bit must be set at each new start of the SIMOTION D435 or when changing the parameterization. This is the reason that an initialization routine is run in the “FB_BGD_TEMPLATE_FlyingSaw()” and a parameter check is made and the block is brought into a defined state.

Note In the startup task, we recommend that the program startup_SAP() of the unit SAP_FS is used in order to initialize the "FB_BGD_TEMPLATE_FlyingSaw()" block.

The restart bit should also be set there in order to bring the block into a defined state!

Note At restart, the block checks essential technology parameters as well as the existence of saved technology objects

After the block has been successfully initialized, the restart bit is automatically reset.

8.5Error messages

If faults occur in the block itself or in technology objects and technology functions involved while FB_BGD_TEMPLATE_FlyingSaw() is operational, then these are signaled using the block outputs error and ErrorID.

V 1.4

Release 06/06/08

83/107

Page 83
Image 83
Siemens A4027118-A0414 user manual Using the restart bit, Error messages, Restart after a new start