Section A: Prerequisites and objectives

Structure and function

Flying Saw with SIMOTION

A4027118-A0414

3.2Operating states of the "FlyingSaw-FB"

The “FlyingSaw FB” automatically controls the “flying saw” axis to implement the required level of functionality.

This functionality is sub-divided into five operating states so that the sequences at the “flying saw” are implemented as a result of the states or also as a result of the transitions between the states.

This means the user only influences the “flying saw” by specifying the required operating mode with the required parameters.

Fig. 3-2 Operating modes

 

 

4

 

 

 

 

4

 

 

 

 

Manual

 

 

Manual

1

 

0

1

 

 

0

Disable

 

 

 

Error

 

 

Disable

 

 

Error

 

 

2

 

 

 

 

2

 

 

 

 

Startposi-

 

 

Startposi-

 

 

tion

 

 

tion

3

3 Auto- Auto- matic matic

A differentiation is made between the following operating modes:

Error (0)

The “FlyingSaw FB” has detected an error and brought the flying saw axis into a safe state. The fault is still available and the user can evaluate it.

The flying saw axis is stopped and is in the “disable” state.

Disable (1)

The “FlyingSaw FB” is already being used but is in the safety operating state. All of the faults/errors present have been successfully acknowledged.

After a reset, the flying saw axis is in the disabled and stopped state.

Starting position (2)

The flying saw axis moves to the starting position or is located at the