All rights reserved | Saw V1.4.doc |
Copyright ♥ Siemens AG 2008 | Manual SIMOTION Flying |
Section D: Program description
Description of important program elements
Flying Saw with SIMOTION |
•Sequence phases when changing from the “disable” to “manual”
•Sequence phases when changing from the “starting position” to “disable”
•Sequence phases when changing from the “starting position” to “error”
•Sequence phases when changing from the “starting position” to “automatic”
•Sequence phases when changing from the “automatic” to “disable”
•Sequence phases when changing from the “automatic” to “starting position”
•Sequence phases when changing from the “manual” to “disable”
•Sequence phases in "automatic" operation.
•Maximum length of the SyncPos buffer
Static variables
•Description of the data structure of the TO parameters
•Description of the data structure of the user interface with the geometry, machine data and control bits
•Description of the data structure of the error interface with the error IDs of the state change and the RetDINT and FR values of the system commands.
•Description of the data structure of the internal data area of the FlyingSaw FBs. Under no circumstances may users change these values.
•Description of the data structure to manage synchronous positions.
•Description of the data structure for time calculations within the FlyingSaw FBs
•Description of the data structure of the synchronous position detection using measuring function.
10.3Functions of the FB_BGD_Template_FlyingSaw() ("FlyingSaw-FB")
10.3.1Declarations
•Input interface
•Input/output interface
•Output interface
•Internal program data
V 1.4 | Release 06/06/08 | 89/107 |