Siemens A4027118-A0414 user manual Synchronous range, Physical quantity Description

Models: A4027118-A0414

1 107
Download 107 pages 57.56 Kb
Page 19
Image 19

All rights reserved

Saw V1.4.doc

Copyright Siemens AG 2008

Manual SIMOTION Flying

 

Section A: Prerequisites and objectives

 

Structure and function

Flying Saw with SIMOTION

A4027118-A0414

Table 3-1: Explanation of the parameterizable physical quantities

Physical quantity

Description

DistanceToSensor

Distance (clearance) between the axis zero of the "flying saw"

[mm]

and the sensor to sense the material and print mark

 

 

StartPos

Starting position of the cutting unit referred to the axis zero

[mm]

point of the "flying saw".

 

 

SyncPos

Position where the cutting unit reaches the specified material

[mm]

position and material velocity. Starting point of the

 

synchronous range

 

 

EndSyncPos

End point of the synchronous range. If, at this particular

[mm]

position, sawing/cutting has still not been completed, then it is

 

now interrupted.

 

 

EndPos

End point (end position) of the traversing range of the "flying

[mm]

saw"

 

(software limit switch)

 

 

ToStartposVelocity

Velocity for travel to the starting position

[mm/s]

 

ToBackposVelocity

Velocity with which the flying saw returns to its starting position

[mm/s]

 

 

 

GapLength

Length of the gap after the cutting unit has made a cut. This

[mm]

gap is to be additionally created between the cut material and

 

the material web.

 

 

GapVelocity

Superimposed velocity with which the gap is to be created

[mm/s]

 

 

 

GearingRatio

Ratio between measured and effective velocity of the material

 

web.

AccelerationCut

Acceleration value for synchronization motion

[mm/s²]

 

 

 

AccelerationBack

Acceleration value for positioning motion back to the starting

[mm/s²]

position

AccelerationGap

Acceleration value for the higher-level positioning to create the

[mm/s²]

"gap"

 

 

Synchronous range

The synchronous range is located between SyncPos and the

EndSyncPos. The material is cut within this range.

V 1.4

Release 06/06/08

19/107

Page 19
Image 19
Siemens A4027118-A0414 user manual Synchronous range, Physical quantity Description