Parameter

Data type

Initial

Description

 

 

 

value

 

 

Control information

 

 

 

 

Restart

BOOL

false

If the bit is set (e.g. in

 

 

 

 

the StartUp task), then

 

 

 

 

the template executes

 

 

 

 

a re-initialization and

 

 

 

 

resets the bit.

 

 

 

 

This bit must be set

 

 

 

 

for each new start!

 

MaterialIn

BOOL

false

If the bit is set, the

 

 

 

 

material web is in the

 

 

 

 

flying saw area.

 

MaterialInMotion

BOOL

false

If the bit is set, the

 

 

 

 

material web in the

 

 

 

 

flying saw area.is

 

 

 

 

moving.

Fig. 6-3 Matrix of the relevant technology objects (TOs)

 

Axis_Material

Axis_FlyingSaw

 

 

 

Pos_Axis

X

--

Following_Axis

--

X

External_Encoder

(X)

--

Following_Objekt

--

X

Printmark

X

--

 

(X) In realen Anwendungen kann auch auf einen

 