Siemens A4027118-A0414 user manual Restart

Models: A4027118-A0414

1 107
Download 107 pages 57.56 Kb
Page 71
Image 71

All rights reserved

Saw V1.4.doc

Copyright Siemens AG 2008

Manual SIMOTION Flying

Section C: Integrating the core “flying saw” functions

Program environment and interfaces

Flying Saw with SIMOTION

 

 

A4027118-A0414

 

 

 

 

 

 

Parameter

Data type

Initial

Description

 

 

 

value

 

 

Control information

 

 

 

 

Restart

BOOL

false

If the bit is set (e.g. in

 

 

 

 

the StartUp task), then

 

 

 

 

the template executes

 

 

 

 

a re-initialization and

 

 

 

 

resets the bit.

 

 

 

 

This bit must be set

 

 

 

 

for each new start!

 

MaterialIn

BOOL

false

If the bit is set, the

 

 

 

 

material web is in the

 

 

 

 

flying saw area.

 

MaterialInMotion

BOOL

false

If the bit is set, the

 

 

 

 

material web in the

 

 

 

 

flying saw area.is

 

 

 

 

moving.

Fig. 6-3 Matrix of the relevant technology objects (TOs)

 

Axis_Material

Axis_FlyingSaw

 

 

 

Pos_Axis

X

--

Following_Axis

--

X

External_Encoder

(X)

--

Following_Objekt

--

X

Printmark

X

--

 

(X) In realen Anwendungen kann auch auf einen

 

externen Geber zugegriffen werden

 

 

 

V 1.4

Release 06/06/08

71/107

Page 71
Image 71
Siemens A4027118-A0414 user manual Restart