START-UP CHECKLIST FOR 30RA LIQUID CHILLER

START-UP CHECKLIST FOR 30RA LIQUID CHILLER

(Remove and use for Job File)

I.Project Information

JOB NAME ______________________________________________________________________________

ADDRESS _______________________________________________________________________________

CITY ____________________________________________ STATE _______________ ZIP______________

INSTALLING CONTRACTOR ________________________________________________________________

SALES OFFICE ___________________________________________________________________________

START-UP PERFORMED BY ________________________________________________________________

Design Information

CAPACITY

CEAT

EWT

LWT

FLUID TYPE FLOW RATE

P.D.

UNIT MODEL ______________________________ SERIAL ________________________________

II. Preliminary Equipment Check

IS THERE ANY PHYSICAL DAMAGE?￿YES ￿NO

DESCRIPTION ____________________________________________________________________________

________________________________________________________________________________________

1. UNIT IS INSTALLED LEVEL AS PER THE INSTALLATION INSTRUCTIONS.

YES

NO

2. POWER SUPPLY AGREES WITH THE UNIT NAMEPLATE.

YES

NO

3. ELECTRICAL POWER WIRING IS INSTALLED PROPERLY.

YES

NO

4. UNIT IS PROPERLY GROUNDED.

YES

NO

5. ELECTRICAL CIRCUIT PROTECTION HAS BEEN SIZED AND INSTALLED PROPERLY.

YES

NO

6. ALL TERMINALS ARE TIGHT.

YES

NO

7. ALL PLUG ASSEMBLIES ARE TIGHT.

YES

NO

8. ALL CABLES AND THERMISTORS HAVE BEEN INSPECTED FOR CROSSED WIRES.

YES

NO

9. ALL THERMISTORS ARE FULLY INSERTED INTO WELLS.

YES

NO

Chilled Water System Check

 

 

1. ALL CHILLED WATER VALVES ARE OPEN.

YES

NO

2. ALL PIPING IS CONNECTED PROPERLY.

YES

NO

3. ALL AIR HAS BEEN PURGED FROM THE SYSTEM.

YES

NO

4. CHILLED WATER PUMP IS OPERATING WITH THE CORRECT ROTATION.

￿YES

￿NO

 

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

2

PC 903

Catalog No. 533-00047

Printed in U.S.A.

Form 30RA-2T

Pg CL-1

1-03

Replaces: 30RA-1T

Tab

5c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 93
Image 93
Sterling 30RA010-055 manual START-UPCHECKLIST FOR 30RA LIQUID CHILLER, Remove and use for Job File I.Project Information