Sun Microsystems SL8500 manual Open the rear doors of the library

Models: SL8500

1 200
Download 200 pages 19.02 Kb
Page 109
Image 109
5.Open the rear doors of the library.

Powering-off the Library

4.Make sure that the drives are empty by verifying the drive state using the StreamLine Library Console.

Note – Refer to the online help documentation accessible through the Library Console application.

5.Open the rear doors of the library.

6.Locate the power distribution unit (PDU) and move the system power-off/on switch to the OFF position (0).

Note – If the library has a 2N power configuration, you must switch off the system power on both the PDUs.

An AC PDU is shown in FIGURE 4-11.

FIGURE 4-11 AC PDU

1. Retainer

2. LEDs

3. System Power Off/On Switch

Figure 20 illustrates the locations of all power supplies (except for the Customer Interface Module’s front frame area).

96154 • Revision K

Chapter 4 Library Operation 69

Page 109