Sun Microsystems SL8500 manual HLI-PRC Address, Library Storage Module LSM, Panel Designations

Models: SL8500

1 200
Download 200 pages 19.02 Kb
Page 162
Image 162
HLI-PRC Address

Cartridge Address

HLI-PRC Address

HLI-PRC (Host LMU Interface - Panel, Row, Column) address is a four digit comma- separated value (L,P,R,C) representing LSM, Panel, Row, Column. This addressing scheme is used by HLI (Host LMU Interface) clients, including ACSLS and HSC, to represent library components accessible to those HLI clients.

The slot location appears in the following format:

l

l

p

p

r

r

c

c

where:

ll:LSM number (0-3)

pp:Panel

rr:Row in the panel

cc:Column in the row

See “Locating a Cartridge and Drive” on page 50 to locate a cartridge using the Library Console.

Although the library management software follows a five digit numbering scheme as that of the SL8500 address there are significant differences in slot designations, CAP behavior, and other operational considerations as described below (see also “PTP Addressing Scheme” on page 34).

Library Storage Module (LSM)

The SL8500 library has four rails on which robots travel. The host software considers each SL8500 rail as a separate LSM. From top to bottom, SL8500 rails are numbered from 1 - 4 while the host LSMs are numbered from 0 - 3. For example, SL8500 rail 1 is Host LSM 0.

TABLE A-5Rail Numbering

Host

Internal Firmware

 

 

LSM 0

Rail 1

 

 

LSM 1

Rail 2

 

 

LSM 2

Rail 3

 

 

LSM 3

Rail 4

 

 

Panel Designations

Panel 0 = cartridge access port (CAP)

Panel 1 = drive panel

The data cartridge slots start their numbering after the drive bay (Panel 1) forward.

122 StreamLine™ SL8500 Modular Library System User's Guide • March 2007

Revision K • 96154

Page 162
Image 162