Library Complex
■The system PDU, connected directly to the branch circuit, provides AC power to three DC power grids and the electronics control module.
■The N+1 PDU supplies added +48 VDC load sharing power to each of the three DC power grids and an extra
The base power configuration provides power to the:
■Tape drive power supplies
■Robotic rail power supplies
■Customer Interface Module power supplies
■Touch screen operator control panel
■Electronics control module power supplies
Note – The base power configuration does not offer redundant AC power.
2N Power Configuration
The 2N power configuration contains the base power configuration (PDU 1) and a second PDU, PDU number 2.
This configuration provides power to the same components as N+1, plus power for:
■Optional, redundant load sharing power supplies
■Two additional accessory racks for customer components
■Redundant controller cards
Note – The 2N PDU is required for the 2N drive power, 2N robotic power, and also for the additional rack installed.
Library Complex
A library complex is created by connecting two or more SL8500 libraries together with
The maximum size library complex possible consists of either:
■32 libraries for Host Software Component (HSC) systems, connected through PTPs, containing over 320,000 cartridge slots and 2,048 tape drives.
■31 libraries for Automated Cartridge System Library Software (ACSLS) connection, connected through PTPs, containing over 320,000 cartridge slots and 1,984 tape drives.
Note – A library complex with functional