Reserved Slots
Reserved Slots
There are a total of 230 slots within the library that are reserved (that is, not to be used for data cartridge storage); these are listed in TABLE
TABLE
Number of Slots | Use for | Location |
|
|
|
198 | Diagnostic or Cleaning Cartridges | Front section of Customer Interface Module |
|
| (separated from data cartridge cells by the Service |
|
| Safety Door area) |
|
|
|
24 | Front section of Customer Interface Module | |
| endstop label (top) |
|
| proximity sensing (middle) |
|
|
| |
| (bottom) |
|
|
|
|
8 | Top cell under the PTP area | |
|
|
|
Total = 230 |
|
|
|
|
|
|
|
|
|
|
|
Cartridge Address
You have to understand two types of addressing scheme to manually locate a cartridge:
■Internal firmware address
■
Internal Address
The internal library firmware designates cartridge locations with a
Library number: The number within a library or library complex
Rail number: Rails are numbered 1 through 4; Rail 1 is the top rail
Column number: Columns are “signed” numbers referenced from the customer interface module, where +1 is right of the center of the drive bays and
Side number: Outer walls = 1, inner walls = 2
Row number: Numbered consecutively, from the top (1) down
See “Locating a Cartridge and Drive” on page 62 to locate a cartridge using the Library Console.
110 StreamLine™ SL8500 Modular Library System User's Guide • March 2007 | Revision K • 96154 |