After changing the variable's value, the CPU will respond with:

V VARIABLE=VALUE WARNLO WARNHI [DATALO-DATAHI] <CRLF>

which should reflect the new value. The values in square brackets are not required for all variables. If needed, the values are included on the command line, separated by spaces. For example, to change the instrument ID, the host computer would issue a command like this:

V MACHINE_ID=1234<CRLF>

and the CPU should respond with:

V DDD:HH:MM IIII MACHINE_ID = 1234 (0-9999)<CRLF>

Table 7-9lists the variable names that are variable through the RS-232 interface and their corresponding button sequences.

Table 7-9: RS-232 Variable Names

Variable Name

Button Sequence

Legal Values

MACHINE_ID

SETUP-MORE-COMM-ID

0000 - 9999

 

 

 

BAUD_RATE

SETUP-MORE-COMM-BAUD

300, 1200, 2400, 4800, 9600, 19.2

 

 

 

CURR_TIME

SETUP-CLK-TIME

00:00 - 23:59

 

 

 

CURR_DATE

SETUP-CLK-DATE

01/01/00 - 12/31/99

 

 

 