Thermador PRD30, PRD48, PRD36 Safety, Gas and Electrical, Requirements and, Grounding Instructions

Models: PRD30 PRD36 PRD48

1 106
Download 106 pages 60.11 Kb
Page 5
Image 5
Safety

require a conversion kit. Make certain your range and gas type are the same. Refer to the product rating label which can be located as indicated on Page 45.

CAUTION

When connecting the unit to propane gas, make certain the pro- pane gas tank is equipped with its own high-pressure regulator in addition to the pressure regulator supplied with the range. The maximum gas pressure to this appliance must not exceed 14.0 inches water column (34.9 mb) from the propane gas tank to the pressure regulator.

Important: All ranges must be installed with a backguard. The 30" model comes with a low back. For all other models, one of three available backguards must be ordered separately and installed at the back of the range. The three backguard choices include a Low Back, Pot and Pan Shelf, or Island Trim. Before using the range, insure that it is equipped with a proper backguard. DO NOT attempt to use a backguard that is not designed to fit your particular model range. Refer to the Installation Instructions accompanying this appliance for more information.

WARNING

To avoid possible burn or fire hazard, a backguard designed specif- ically for this range must be installed whenever the range is used.

This manual contains important Care and Use information for all Thermador Profes- sional® Ranges. When using this manual, it is critical that you know the model num- ber of your range, as some information will be unique to each range. The model number may be found on the rating plate located on the range as identified on Page 45 of this manual. The charts on the following pages summarize the various range models and identify the features of each range.

Safety

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Gas and Electrical

PLEASE READ CAREFULLY

Requirements and

30" Dual-Fuel Models:

Grounding Instructions

240/208 volts, 60 Hz., 35 Amp electrical circuit required for each line.

 

36" Dual-Fuel Models:

 

240/208 volts, 60 Hz., 35 Amp electrical circuit required for each line.

 

48" Dual-Fuel Models:

 

240/208 volts, 60 Hz., 50 Amp electrical circuit required for each line.