Thermador PRD48 Before Calling For Service, Symptom, Cause, Remedy, If the Burners do not Ignite

Models: PRD30 PRD36 PRD48

1 106
Download 106 pages 60.11 Kb
Page 48
Image 48
SYMPTOM

SYMPTOM

CAUSE

REMEDY

 

• Electrical power supply is incor-

• Refer to Installation Instructions.

 

rectly polarized.

Have a qualified electrician ground the

 

 

range properly.

Before Calling For Service

Before calling for service, check the following to avoid unnecessary service charges.

Be sure to check these items first:

Is there a power outage in the area?

Is the household fuse blown or the circuit breaker tripped?

Is the range disconnected from the electrical supply?

If the Burners do not Ignite

Are the burner caps properly aligned and seated in the burner bases?

Are the burner ports clogged?

Is a fuse blown or is the circuit breaker tripped?

Is the manual shut-off valve closed, preventing the flow of gas?

Data Rating Plate

The data rating plate shows the model and serial number of your range. It is located under the front edge of the range's cooktop, and is visible when the oven door is open (See illustration).

Rating plate(s) located

under front edge of

cooktop.

Wiring/schematic dia-

grams placed behind toe

kick panel.

Figure 24: Rating Plate and Wiring Diagram Locations (oven door not shown)

The electric wiring diagrams and schematics in the toe kick area should not be removed except by a service technician. Replace after service.