Removal (Fig. 59)

NOTE: The ports on the manifold are marked for easy

identification of components. Example: P1 is a piston pump connection port and SV is the location for the sole- noid valve (See Hydraulic Schematic in Chapter 9 -- Foldout Drawings to identify the function of the hydraulic lines and cartridge valves at each port).

1.Read the General Precautions for Removing and Installing Hydraulic System Components at the begin- ning of this section.

2.To prevent contamination of hydraulic system during manifold removal, thoroughly clean exterior of manifold and fittings.

3.Disconnect electrical connector from the solenoid valve.

4.Disconnect hydraulic lines from manifold and put caps or plugs on open hydraulic lines and fittings. Label disconnected hydraulic lines for proper installation.

5.Remove hydraulic manifold from the frame using Figure 59 as guide.

Installation (Fig. 59)

1.Install hydraulic manifold to the frame using Figure

59as guide.

2.Remove caps and plugs from fittings and hoses. Properly connect hydraulic lines to manifold.

3.Connect electrical connector to the solenoid valve.