Toro 4100-D service manual System

Models: 4100-D

1 298
Download 298 pages 42.12 Kb
Page 169
Image 169

Removal (Fig. 94)

1.Read the General Precautions for Removing and Installing Hydraulic System Components at the begin- ning of the Service and Repairs section of this chapter.

2.To prevent contamination of hydraulic system during manifold removal, thoroughly clean exterior of manifold and fittings.

3.Disconnect hydraulic lines from manifold and put caps or plugs on open hydraulic lines and fittings. Label disconnected hydraulic lines for proper reassembly.

4.Remove hydraulic manifold from the frame using Figure 94 as guide.

5.If hydraulic fittings are to be removed from manifold, mark fitting orientation to allow correct assembly. Re- move fittings from manifold and discard O--rings.

Installation (Fig. 94)

1.If fittings were removed from manifold, lubricate and place new O--rings onto fittings. Install fittings into man- ifold openings using marks made during the removal process to properly orientate fittings. Tighten fittings (see Hydraulic Fitting Installation in the General Infor- mation section of this chapter).

2.Install hydraulic manifold to the frame using Figure

94as guide.

A.If valve plate (item 2) was removed, tighten lock nut (item 7) until washer begins to seat in isolator (item 5). Do not cause isolator to be deformed during valve plate installation.

3.Remove caps and plugs from fittings and hoses. Us- ing labels placed during manifold removal, properly con- nect hydraulic lines to manifold.

System

Hydraulic

Groundsmaster 4100--D

Page 4 -- 135

Hydraulic System

Page 169
Image 169
Toro 4100-D service manual System