Removal (Fig. 61)
1.Read the General Precautions for Removing and Installing Hydraulic System Components at the begin- ning of the Service and Repairs section of this chapter.
2.To prevent contamination of hydraulic system during manifold removal, thoroughly clean exterior of manifold and fittings.
3.Disconnect hydraulic lines from manifold and put caps or plugs on open hydraulic lines and fittings. Label disconnected hydraulic lines for proper reassembly.
4.Remove filter manifold from the frame using Figure
61as guide.
5.If hydraulic fittings are to be removed from manifold, mark fitting orientation to allow correct assembly. Re- move fittings from manifold and discard
Installation (Fig. 61)
1.If fittings were removed from manifold, lubricate and place new
2.Install filter manifold to the frame using Figure 61 as guide.
3.Remove caps and plugs from fittings and hoses. Us- ing labels placed during manifold removal, properly con- nect hydraulic lines to manifold.
System
Hydraulic
Groundsmaster | Page 4 | Hydraulic System |