General Information
Operator’s Manual
The Operator’s Manual provides information regarding the operation, general maintenance and maintenance intervals for your Groundsmaster machine. Refer to that publication for additional information when servicing the machine.
Towing Traction Unit
IMPORTANT: If towing limits are exceeded, severe damage to the piston pump may occur.
If it becomes necessary to tow (or push) the machine, tow (or push) in a forward direction only and at a speed below 3 mph. The piston (traction) pump is equipped with a
1
Figure 1
1.
Hydraulic System
Check Hydraulic Fluid
The Groundsmaster
ervoir holds approximately 8 gallons (30.3 liters) of1 hydraulic fluid. Check level of hydraulic fluid daily.
See Operator’s Manual for fluid level checking proce- dure and hydraulic oil recommendations.
Figure 2
1. Hydraulic reservoir cap
Groundsmaster | Page 4 | Hydraulic System |