5. SYSTEM MODE
Print condition:
Label length Print method Sensor type Speed
Issuing number Issuing mode Other
<< COUNTER >>
Item
Count condition
TOTAL FEED

EO18-33027

5.3 SELF-DIAGNOSTIC TEST

 

 

490mm

 

 

Setting by user

 

 

Non

 

203dpi

6ips

 

305dpi

5ips

 

 

1 piece

 

 

Setting by user

 

 

No mount winding motor

Content

Range

Total label distance covered (cannot be 0.0 3200.0 km cleared)

Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse

feed operation.)

When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.

FEED

Label distance covered

0.0 3200.0 km

Counts when the paper feed motor are driven to feed a paper or print. (Counts also during a reverse

feed operation.)

When the power is off, the label distance of 50.0 cm or less may be rounded down and backed up.

FEED1 FEED4

Label distance covered historical

0.0

3200.0 km

 

 

 

 

The label historical distance.

 

 

PRINT

Print distance

0.0

200.0 km

Counts while printing. (Counting is not performed during reverse feed operation.) B-EX4T1-G:

When the power is off, the print distance of 8.2 m or less is rounded down and backed up. B-EX4T1-T:

When the power is off, the print distance of 5.5 m or less is rounded down and backed up.

PRINT1 PRINT4

Print distance historical

0.0 3200.0 km

The historical print distance.

 

CUT

Cut count

0 1000000

Every cut operation is counted.

When the power is off, a cut count of 31 or less is rounded down and backed up.

HEAD U/D

Head up/down count

0 2000000

Counts head up/down operations using the ribbon saving solenoid. (Combination of up and down operations is counted as one.)

When the power is off, an up/down count of 31 or less is rounded down and backed up.

RIBBON

Ribbon motor drive time

0 2000 Hour

Counts when the ribbon motor is driven to feed a paper or print. (Counts also during a reverse feed operation.)

For B-EX4T1-G:

When the power is off, a drive time of 32 seconds or less is rounded down and backed up. For B-EX4T1-T:

When the power is off, a drive time of 27 seconds or less is rounded down and backed up.

SOLENOID

Head-up solenoid drive time

0 1000 Hour

Counts when the ribbon saving operation is performed. For B-EX4T1-G:

When the power is off, a drive time of 32 seconds or less is rounded down and backed up. For B-EX4T1-T:

5-6

Page 54
Image 54
Toshiba B-EX4 manual FEED1 ~ FEED4, Print, PRINT1 ~ PRINT4, Cut, Head U/D, Ribbon, Solenoid