5. SYSTEM MODE

EO18-33027

5.8 RAM CLEAR

5.8 RAM CLEAR

„Outline of RAM Clear

In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible. After replacing the print head, ribbon motor, or platen, perform maintenance clear.

The RAM Clear menu contains the following:

MENU ITEM

System Mode / SYSTEM MODE <6>RAM クリア / <6>RAM CLEAR

Clear Disable / NO RAM CLEAR

Counter clear / MAINTE.CNT CLEAR

All counter / ALL COUNTER

Label distance covered / FEED

Print distance / PRINT

Cut count / CUT

Others / OTHER

Parameter clear / PARAMETER CLEAR

QM type / QM TYPE

JA type / JA TYPE

CN type / CN TYPE

5.8.1 No RAM clear / NO RAM CLEAR

This is a selection to prevent wrong user operation.

5.8.2 Counter clear / MAINTE.CNT CLEAR

It clears maintenance counter, like label distance covered etc.

Initial value after maintenance counter clear

Item

Initial value

Label distance covered

0

km

Print distance

0

km

Cut count

0

 

Head up/down count

0

 

Ribbon motor drive time

0 hours

Head-up solenoid driver time

0 Hours

RS-232C hardware error count

0

 

System error count

0

 

Momentary power interruption

0

 

count

 

 