5. SYSTEM MODE

EO18-33027

5.11 RFID Module Setting

5.11.3.2Issue retry label / ISSUE RETRY LABLES

This is a issue retry number after printing error pattern (void pattern) automatically when RFID write error occur. Printer stop as RFID write error if RFID write does not success after retrying this number.

Max.

Min.

Step

Display

Sign

Integer

Decimal

0 fullfil

Unit

 

 

 

 

 

digit

point

 

 

 

 

 

 

 

 

digit

 

 

255

0

1

Decimal

Non

3

0

Non

Labels

 

 

 

 

 

 

 

 

 

5.11.3.3Read retry / READ RETRY

It sets reading retry count and reading retry time.

The printer retries to read the data in the RFID tag for up to specified number of times. If the time-out has come before the maximum number retries have been done, the printer stops the retries at the time. Whenever the printer writes data onto the RFID tag, the tag is read first. The maximum number of retries set by this parameter becomes also effective in this pre-read.

Max.

Min.

Step

Display

Sign

Integer

Decimal

0 fullfil

Unit

 

 

 

 

 

digit

point

 

 

 

 

 

 

 

 

digit

 

 

255

0

1

Decimal

Non

3

0

Non

times

 

 

 

 

 

 

 

 

 

Set the time-out for retry to read the RFID tag.

If the printer has retried for the maxim number of times within the RFID read retry time-out, the printer stops the retries at the time.

Whenever the printer writes data onto the RFID tag, the tag is read first. The read retry time-out set by this parameter becomes also effective in this pre-read.

Max.

Min.

Step

Display

Sign

Integer

Decimal

0 fullfil

Unit

 

 

 

 

 

digit

point

 

 

 

 

 

 

 

 

digit

 

 

9.9

0.0

0.1

Decimal

Non

1

1

Non

second

 

 

 

 

 

 

 

 

 

5-78

Page 126
Image 126
Toshiba B-EX4 manual 11.3.2Issue retry label / Issue Retry Lables, Digit 255 Decimal Non, 11.3.3Read retry / Read Retry