5. SYSTEM MODE

EO18-33027

5.3 SELF-DIAGNOSTIC TEST

<< PARAMETER SETTINGS >>

Item

Content

 

Print value

 

 

 

 

MEDIA LOAD

Media loading

OFF

Disable

 

 

 

 

 

 

 

STD

Feed

detected

gap/mark

 

 

 

to stop position.

 

 

 

 

 

ECO

Feed

gap/mark

between

 

 

 

head and sensor to stop

 

 

 

position.

 

 

 

 

 

 

 

ECO+BFeed

Perform

back

feed

after

 

 

 

completion of ECO.

 

FORWARD WAIT

Forward feed standby after

ON

Performed

 

 

 

 

 

an issue

 

(A fine

adjustment

value

 

 

 

for the stop position is

 

 

 

also printed.)

 

 

 

 

 

OFF

Not performed

 

 

 

FW/BK ACT.

Forward feed standby action

MODE1

Stops after 13.7-mm

 

 

 

forward feed.

 

 

 

 

 

MODE2

Stops after 6-mm back

 

 

 

feed and 3-mm forward

 

 

 

feed. (Only when the cut

 

 

 

mode,

thermal

transfer,

 

 

 

and feed gap sensor are

 

 

 

selected.) In other cases,

 

 

 

the

printer

stops

after

 

 

 

13.7-mm forward feed.

HU CUT/RWD.

Head-up operation in cut

ON

Head-up operation is

 

 

issue mode, or use of the

 

performed, or the

 

 

 

rewinder

 

rewinder is used.

 

 

 

 

OFF

Head-up operation is not

 

 

 

performed,

 

or

the

 

 

 

rewinder is not used.

 

RBN SAVE

Ribbon saving system

ON(TAG)

Used when the head lever

 

setting

 

position is “TAG”

 

 

 

 

ON(LBL)

Used when the head lever

 

 

 

position is “LABEL”.

 

 

 

OFF

Not used

 

 

 

 

PRE PEEL OFF

Pre-peel-off process setting

ON

Pre-peel-off operation is

 

 

 

performed.

 

 

 

 

 

 

OFF

Pre-peel-off operation is

 

 

 

not performed.

 

 

 

BACK SPEED

Back feed speed setting

STD

3ips

 

 

 

 

 

 

 

 

LOW

2ips

 

 

 

 

 

 

AUTO CALIB

Auto calibration setting

OFF

Auto

calibration

is

not

 

 

 

preformed.

 

 

 

 

 

 

ON TRANS.

Auto

 

calibrating

is

 

 

 

performed

 

 

 

by

 

 

 

transmissive sensor.

 

 

 

ON REFLECT

Auto

 

calibrating

is

 

 

 

performed

by

 

reflective

 

 

 

sensor.

 

 

 

 

 

 

 

ON ALL

Auto

 

calibrating

is

 

 

 

performed

by

 

both

 

 

 

sensor.

 

 

 

 

 

 

 

ON

Perform

back

feed

after

 

 

TRANS.+Bfeed

movement

 

of

ON

 

 

 

TRANS.

 

 

 

 

5-8