5. SYSTEM MODE

EO18-33027

5.4 PARAMETER SETTING

Example of TYPE2

Case 1

Issuing number = 5, When label end is detected at 3rd label issuing.

(1)(2) (3)

Stop by error after (3), LCD: “NO PAPER 2”

When printer is restarted, issue (4) (5) after initial feed.

The complete issued label is (1) (2) (3) (4) (5).

Case 2

Issuing number = 5, When label end is detected at 3rd label issuing. The remaining label length is longer than 30 mm.

(1)(2) (3)

Stop printing after 20mm printing as error, LCD: “NO RIBBON 2”

When printer is restarted, issue (4) (5) after initial feed.

The complete issued label is (1) (2) (4) (5).

Case 3

Issuing number = 5, When label end is detected at 3rd label issuing. The remaining label length is shorter than 30 mm.

 

 

(1) (2) (3)

 

 

 

 

Stop printing after issuing (3) as error, LCD: “NO RIBBON 2”

 

 

When printer is restarted, issue (4) (5) after initial feed.

 

 

The complete issued label is (1) (2) (3) (4) (5).

 

 

5.4.2.15 MaxiCode specification / MAXI CODE

TYPE1

Compatible with the current version

TYPE2

Special specification

The mode specified by the command may be different from the actual mode, depending on the status

of

this

parameter.

Also,

the

data

transmission

method

differs

partly.

For details, refer to the External Equipment Interface Specification (EAA-03466).

5.4.2.16 XML

Disable / OFF

Standard / STD

Oracle / ORACLE

SAP

Standard external / STD EXT

Oracle external / ORACLE EXT

SAP external / SAP EXT

Disable XML function Standard specification Specification for Oracle Specification for SAP

Standard specification (Use external memory) Specification for Oracle (Use external memory) Specification for SAP (Use external memory)

5-32

Page 80
Image 80
Toshiba B-EX4 manual MaxiCode specification / Maxi Code, Compatible with the current version, 2.16 XML, ・ Sap