Toshiba B-EX4 manual Test Option

Models: B-EX4

1 173
Download 173 pages 8.28 Kb
Page 162
Image 162

11. RFID ANALYZE TOOL

(4)Test Option

EO18-33027

11.3 Application Functions

This menu is available only when the U2 type is selected. (However, when the U1 type is selected, only the Power Level Change and Level Range are programmable.)

PWR Level Change

 

 

 

 

 

AGC Read Value

 

 

 

 

 

 

Level Range: Start

 

 

 

 

 

 

 

(9 to 18)

 

 

 

 

 

 

Level Range: End

 

 

 

 

 

 

 

 

 

 

 

 

(9 to 18)

 

 

 

 

 

Reading Range

Level Range: Step

 

 

 

 

 

 

 

 

 

 

 

PWR Level Change (Power Level Change)

When checked, a write or read test can be performed while changing the output level of the RFID module, without changing the tag position. This enables finding the optimal output level for writing data onto the tag.

Setting range of the power level: B-EX700-RFID-U2-EU/US-R: 9 to 18

Start: Enables setting the value for the starting power level.

End: Enables setting the value for the starting power level.

Step: Enables setting the step value. AGC Read Value:

When checked, the Advanced Gain Control (AGC) data is read every time a tag is written or read. Rank Data: Rank Data is equal to the AGC threshold value of the printer.

Value Data: Value data is the value sent from the RFID module without any conversion. Usually, the rank data is used.

Reading range:

The read range of the tag is searched.

The positions where the error “e36” does not occur are considered as OK (readable). The positions where no response is returned from the tag are considered as an error.

Error code: “e31”: Timeout (Tag is existing.)

“e35”: Data write failed. (Tag is existing.)

“e36”: Tag is not existing.

“e37”: Communication error (Tag is existing.)