Notes to Users

Step 1: Safety Approval

Toshiba Information System (U.K.) Ltd declare that the Strata CT complies with the EEC’s LVD directive, (Directive No. 73/23/EEC). The product has been assessed and found to comply with EN60950:2000.

The notes listed below form part of the products compliance with the aforementioned European Norm.

1-1. The system, PCOU/RCOU/RCOS unit, must be earthed. The earth connection must be hardwired to a main distribution point. The main cabinet must be earthed.

1-2. Table A1 below identifies and classifies the ports available on the system:

Table A1

Type of Circuit

 

 

(EN60950

Port Location

Port Description

Classification)

 

 

SELV

Power Supply

For connection of external 24 volt batteries.

 

BPSU672F

 

 

 

 

SELV

Processor Boards:

For connection of external Music-on-Hold source

 

B1CU1F, B2CAU1A,

 

 

B3CAU1A, B5CAU1A

 

 

 

 

SELV

PDKU2A

For connection of Toshiba propriety terminals.

 

 

 

SELV

PEKU2F

For connection of Toshiba Visually Handicapped Console terminals.

 

 

 

TNV3

RSTU1F

For connection of approved 2 wire devices.

 

 

 

TNV3

RSTU3F

For connection of approved 2 wire devices.

 

 

 

TNV3

PCOU2F/PCOUS2F

For connection to PTO provided Loop Call Unguarded Clear

 

 

exchange lines.

 

 

 

TNV3

RCOU3F/RCOS3F

For connection to PTO provided Loop Call Unguarded Clear

 

 

exchange lines.

 

 

 

Strata CT Digital Telephone User Guide November 2001

169

Page 185
Image 185
Toshiba DKT2510-FSD, DKT2520-FSD manual Safety Approval, 169