Troubleshooting Procedures

 

 

 

 

F116

S3 shift start

RAM

CN1400, CN1410 (RAM

 

Conn.)

 

 

 

F117

S4 shift start

RAM

CN1400, CN1410 (RAM

Conn.)

 

 

 

F118

S5 shift start

RAM

CN1400, CN1410 (RAM

Conn.)

 

 

 

F119

USB electric supply setting

PCH

IC1600 (PCH)

start

EC

IC3200 (EC/KBC)

 

F11A

Completion of a USB

PCH

IC1600 (PCH)

electric supply setting

EC

IC3200 (EC/KBC)

 

F11B

Shutdown processing

RAM

CN1400, CN1410 (RAM

Conn.)

 

 

 

F11C

Completion of Shutdown

RAM

CN1400, CN1410 (RAM

processing

Conn.)

 

 

F11D

S3 return service start

BIOSROM

IC3000/IC3002 (BIOS

ROM), CN1400, CN1410

RAM

 

 

(RAM Conn.)

 

 

 

F1FF

End of S3 return processing.

RAM

CN1400, CN1410 (RAM

Shifts to OS.

Conn.)

 

 

NOTE: Status outputted by the test means the last error detected in the debug port test.

Check 1 If the D port is status F11Eh or F120h is displayed, go to “HDD Trouble shooting Procedure in Section 2.6.

Check 2 If any other D port status error code is displayed, perform Procedure 3. D port error code is as follows:

Error code

Contents

 

 

F003h or F004h

SC initialization error

 

 

F00Bh

BIOS update error

 

 

F117h

Exception check error

 

 

F121h

Clock generator error

 

 

2-28 [CONFIDENTIAL] TECRA M11/Satellite Pro S500M Series Maintenance Manual (960-813)