Western Telematic AFS-16-1 Appendix B. Specifications, Switching, Physical/Environmental, Apx-2

Models: AFS-16-1

1 135
Download 135 pages 23.28 Kb
Page 125
Image 125

Appendix B. Specifications

Switch Card: Up to 16 Modules

Interface: RJ45-3, Three Jacks, 8 Pins Switched Common Jack to A or B Jack.

Contacts: High Reliability, Mechanical Relays, Break-Before-Make Contacts with 1 Amp @ 30 VDC Rating, 100 Million Cycle Life.

Switching:

Manual: Individual Toggle Switch, Gang Switching from Control Module.

Code/Web Browser: By Slot Number or by Name.

Card Rack and Control Unit

Ethernet Port: 10/100Base-T

Serial Console Port: 1 each, RJ45, RS232C

AUX Port: 5-Pin Quick-Connect Terminal Block for External Connection for Alarm Output, Monitor Input and Ground. Monitor Input Signal is always read relative to ground signal.

Low Monitor Input Signal: 0V to -48V

High Monitor Input Signal: +5V to +48V

RS232 Port Interface:

Connectors: One (1) RJ45 connector (DTE pinout.)

Coding: 7/8 bits, Even, Odd, No Parity, 1, 2 Stop Bits.

Flow Control: XON/XOFF, RTS/CTS, Both, or None.

Data Rate: 300 to 115.2K bps (all standard rates).

Inactivity Timeout: No activity timeout disconnects port/modem sessions. Off, 5, 15, 30, 90 minutes.

Break: Send Break or Inhibit Break

Site ID: 32 Characters.

Port Name: 16 Characters per port.

Usernames & Passwords: 32 character usernames; 16 character passwords (case sensitive.) Up to 128 pairs, definable circuit module, circuit group and

system access.

Physical/Environmental:

Size: 5.25” x 19.00” x 6.75” (H x W x D)

Power: 100/240 VAC 50/60 Hz, 15 watts

Weight: Shipping Weight, Fully Loaded, 15 pounds

Operating Temperature: 32˚F to 122˚F (0˚C to 50˚C)

Humidity: 10 - 90% RH

Venting: Side vents are used to dissipate heat generated within the unit. When mounting the unit in an equipment rack, make certain to allow adequate clearance for venting.

Apx-2

Page 125
Image 125
Western Telematic AFS-16-1 manual Appendix B. Specifications, Switching, Physical/Environmental, Apx-2