5-20
Basic Configuration
5.6. Circuit Configuration
The Circuit Parameters menu allows you to select parameters for the AFS-16 Circuit
Modules. This allows you to assign names to the A, C, and B connectors on each
Circuit Module, and also define a default A/B setting for each A/B Switch. Note that the
Circuit Parameters menu is only available when you have logged into command mode
using an account that permits Administrator commands. The Circuit Parameters Menu
allows you to define the following parameters:
• Name(Common): Assigns a name to the Common RJ45 connector on the
selected Circuit Module.
• Name(A): Assigns a name to the "A" RJ45 connector on the selected
Circuit Module.
• Name(B): Assigns a name to the "B" RJ45 connector on the selected
Circuit Module.
• PowerUpDefault: Determines how this A/B Switch will react when the "Default All
Circuits" command (/DF) is invoked, or after power to the unit has been interrupted
and then restored. After the default command is invoked, or power is restored, the
AFS-16 will automatically set each A/B Switch to the "A" or "B" setting as specified
by the Power-Up Default. (Default = "A").
Notes:
• Ifyouhaveaccessedcommandmodeusinganaccountthathas
AdministratororSuperUserlevelcommandaccess,thentheDefault
commandwillbeappliedtoallCircuitModules.
• IfyouhaveaccessedcommandmodeusinganaccountthathasUserlevel
commandaccess,thentheDefaultcommandwillonlybeappliedtothe
CircuitModulesthatareallowedbyyouraccount.
• TheDefaultcommandisnotavailabletoViewOnlylevelaccounts.