READ-by-ID

Operator Interface

READ-by-ID

The Read-by-ID feature supports the ability of the user to view any Read or Write parameter available within the menu structure. It also provides a means to view data logging and accumulated values information. See Table 2-2for a list of the Read Menu parameters. See Table 2-3for a list of data logging menu parameters. See Table 2-4for a list of accumulated values parameters.

To use the Read-by-ID Feature:

1.From the Standard Display, press the \/ key three times to scroll downward through the menu to the Read-by-ID Menu item. Stop when the 3rd and 4th line of the display change as shown in Figure 2-6.

2.Press <ENTER> to enter the Read-by-ID feature.

3.Use the keypad to enter the ID number of the Data Log Configuration or Accumulated Value ID number and press <ENTER>. See Table 2-2for a list of READ Menu items and their ID numbers.

a)Press the “.” button to move upward in the Menu structure.

b)Press the “-” to move backward in the menu structure. These keys only function in the Read-by-ID feature.

System: Shutdown

Inv: Standby

Hit ENTER or "." "-" To use the Read-by-ID Feature:

Value by ID#

Press <ENTER> when this screen appears to access the Read-by-ID feature.

System: Shutdown

Inv: Standby

Hit ENTER or "." "-"

Read ID# xxx: xxx

Use the keypad to enter the desired ID number and press <ENTER>.

The display will change as shown and will show the requested value.

where:

xxx = any Menu ID

xxx = operational value of Menu ID

Use the “.” and “-” buttons to scroll backward and forward within the Read-by-ID menu.

Figure 2-6Read-by-ID Feature