Xantrex Technology PV100S-208 1 Fault Codes, Error, Fault Type, Fault Sources, Fault Description

Models: PV100S-208

1 124
Download 124 pages 2.86 Kb
Page 95
Image 95
Manual background

 

 

 

 

 

Fault Code Descriptions

 

 

 

 

 

 

Table 4-1Fault Codes

 

 

 

 

 

 

 

 

 

 

Error

 

Fault Type

 

 

 

 

H=Hardware

 

 

 

Code

Fault Source(s)

S=Software

Fault Description

Possible Causes

 

 

 

 

 

XX62

Matrix Temperature

S

This fault indicates that the PV100S

• Fuses F15 or F16 blown

 

 

 

has detected that the temperature of

External cooling fan

 

 

 

the IGBT matrix aluminum heatsink

 

inoperable

 

 

 

has exceeded the maximum allowed

• Air flow on heat sink

 

 

 

value of 95 °C.

 

impeded due to

 

 

 

 

 

accumulation of debris

 

 

 

 

Operation above rated

 

 

 

 

 

ambient temperature for

 

 

 

 

 

an extended period of

 

 

 

 

 

time

 

 

 

 

 

0070

Interlock Activated

H

This fault indicates that the PV100S

• Door is open and

 

 

 

has detected that the door of the Main

 

interlock switch is

 

 

 

Inverter enclosure is open and the

 

active

 

 

 

door interlock switch is in the active

Interlock switch is

 

 

 

position. This fault is primarily for

 

inoperable

 

 

 

personnel safety. Opening the door of

• P2 or P3 on CCU2 is

 

 

 

the Main Inverter enclosure while the

 

loose or disconnected

 

 

 

PV100S is processing power will

CCU2 +/-15Vdc Power

 

 

 

cause an immediate orderly shutdown

 

Supply is defective

 

 

 

of the system.

 

 

 

 

 

 

 

0071

PV Switch Open

H

This fault indicates that the PV100S

• DC disconnect switch is

 

 

 

has detected that the DC disconnect

 

open and auxiliary

 

 

 

switch (S2) is open and the auxiliary

 

switch is active

 

 

 

switch is in the active position. This

Auxiliary switch is

 

 

 

fault is primarily for personnel safety.

 

inoperable

 

 

 

Opening the DC disconnect switch

• P2 or P3 on CCU2 is

 

 

 

while the PV100S is processing

 

loose or disconnected

 

 

 

power will cause an immediate

• CCU2 +/-15 Vdc Power

 

 

 

orderly shutdown of the system.

 

Supply is defective

 

 

 

 

 

 

0074

Fused PV Contactor

S

This fault indicates that the PV100S

K2 is inoperable

 

 

 

has detected that upon system

SSR2 is inoperable

 

 

 

shutdown, the DC bus voltage has

 

 

 

 

 

remained within 5% of the DC input

 

 

 

 

 

voltage for more than 10 seconds.

 

 

 

 

 

This condition is indicative of a fused

 

 

 

 

 

PV contactor (K2).

 

 

 

 

 

 

 

 