Specifying input parameters

Syntax [ac:] PCC ASSIGN = {(byte, ccln) (byte, (ccln1 [, ccln2] [, ...])}

Syntax for ccln definition:

{field1[, field2 [, field3]] (field1 [, field2 [, field3]] [, {TOF OVR

IGN}])}

Options

Table 2-33. PCC ASSIGN parameter options and definitions

Option

Definition

 

 

 

 

 

byte

The printer carriage control byte that is being defined. Its value is in the range 0 to 255

 

(X00 to XFF).

 

 

 

ccln

carriage control line number.

 

Specifies the action that should be taken when the printer carriage control byte defined

 

in the byte field is encountered.

 

A ccln consists of the following:

 

Space print parameters

 

This has the following components:

 

field1

Specifies the carriage action to take before printing. (An example is the

 

 

 

ANSI carriage control.)

 

 

-

SPm Space m lines before printing.

 

 

-

SKn Skip to channel n before printing.

 

field2

Specifies whether printing occurs for this record:

 

 

-

P Print the output data at the line number computed after field1 is

 

 

 

processed.

 

 

-

N No printing occurs for this record (default).

 

field3

Specifies the carriage action to take after printing. (An example is the

 

 

 

IBM1403 carriage control).

 

 

- SPm Space m lines after printing.

 

 

- SKn Skip to channel n after printing.

NOTE: Each of the three fields shown above is optional; however, you must specify at least one field. The range for variables m and n is 0 to 15.

Bottom Of Form actions (optional)

TOF

When spacing causes bottom of form (BOF) to occur, instructs the system to go to the top of form (TOF) on the next page and to stop spacing.

IGN

When spacing causes the bottom of form (BOF) to occur, instructs the system to ignore it to continue spacing through the end of the physical page. The page then transitions to top of form and spacing continues.

OVR (default)

When spacing causes bottom of form (BOF) to occur, instructs the system to go to the top of form (TOF) on the next page and to continue spacing.

Default No default

2-32

Using LCDS Print Description Language

Page 140