Using logical processing

Points to note: LMODIFY command

The LMODIFY command acts upon individual print lines. The offset values in all of the test criteria are measured from the beginning of the print line to the beginning of the test field.

The print data offset (pdo value) in the LINE DATA parameter can affect the relationship between the beginning of the input data record and the beginning of the print line.

NOTE: In the LMODIFY command, the offset is measured differently from the way it is done for other PDL commands. The offset value for LMODIFY is measured from the beginning of the print line. In most cases, the offset value is measured from the beginning of the user portion of the record.

Copy modification entries (CMEs) or font indexing (and optionally ink indexing) in conjunction with OVERPRINT=MERGE override LMODIFY specifications.

RAUX command

You can control feeding of a single sheet of paper from the tray that contains the AUX stock, from within the input data stream. If the system encounters a data record that satisfies the RAUX test criteria, the page on which the record is found prints on a sheet of paper picked from the tray assigned to the AUX stock.

For simplex printing, the page is printed on a sheet of paper selected from the current tray, unless the page contains a record satisfying the RAUX test criterion. For duplex printing, the system ascertains the need to pick a sheet from the AUX stock (the specified RAUX criterion appears on either the front or back side of a page) on a page pair basis before the first side is printed.

This command can also be used in combination with the OUTPUT FEED command and the FEED DJDE.

The following section describes the syntax of the RAUX command parameter and explains its options.

Using LCDS Print Description Language

3-33

Page 213
Image 213
Xerox FreeFlow manual Points to note Lmodify command, Raux command