Specifying input parameters

VOLUME BMULT

Specifies a multiplication factor that you can use to determine the true block length.

Syntax VOLUME BMULT = value

Options

Table 2-57. VOLUME BMULT parameter options and definitions

Option

Definition

 

 

 

 

value

An integer from 1 to 15 that you extract from the tape label and apply as a

 

multiplication factor to the block length to determine the true block length

 

 

Default 1

VOLUME CODE

Specifies which code translation table the system uses to interpret the input data.

Syntax VOLUME CODE = {keyword id NONE}

Options

Table 2-58. VOLUME CODE parameter options and definitions

Option

Definition

 

 

 

 

keyword

Specifies a specific, standard, system defined code translation table. The

 

available options are:

 

ASCII

 

BCD

 

EBCDIC

 

H2BCD

 

H6BCD

 

IBMBCD

 

NONE

 

PEBCDIC

 

• USER (Refers to the single unlabeled CODE command defined within the

 

 

JDL.)

 

 

id

Specifies an identifier label that you used in a previously defined CODE

 

command. The id label is required when multiple CODE commands are

 

contained within the JDL.

 

 

NONE

Specifies that data will not be translated by input processing.

 

 

 

2-56

Using LCDS Print Description Language

Page 164
Image 164
Xerox FreeFlow manual Options 57. Volume Bmult parameter options and definitions, Volume Code, Contained within the JDL