Xerox FreeFlow manual Options 95. VFU Assign parameter options and definitions, Vfu Tof

Models: FreeFlow

1 506
Download 506 pages 3.91 Kb
Page 351
Image 351

Specifying print format parameters

Options

Table 4-95. VFU ASSIGN parameter options and definitions

Option

Definition

 

 

 

 

channo

channel number.

 

The number of the channel being assigned. It is an integer in the range 0 to 15.

 

 

lineno

line number.

 

The number of the output print line that you are assigning to a particular

 

channel. It is an integer in the range TOF to BOF.

 

 

 

Default

 

No default

 

 

VFU BOF

 

 

Specifies the Bottom Of Form line number.

Syntax [ac:] VFU BOF = value

Options

Table 4-96. VFU BOF parameter options and definitions

Option Definition

value Specifies the number of lines from the top of the output page to the last print line on the page (bottom of form). The Bottom Of Form specification is independent of channel assignments. BOF should be greater than or equal to the largest line number assigned to a channel.

The maximum value for BOF is 255.

Default 66

VFU BOF If the carriage control action specified by the PCC ASSIGN parameter: point parameter for BOF is specified as OVR (the default), the

to note processing spaces from Top of Form a number of lines equal to the difference between the location of the current line and the new BOF (if it is different from the original BOF).

VFU TOF

Specifies the Top Of Form line number.

Syntax [ac:] VFU TOF = value

Using LCDS Print Description Language

4-111

Page 351