Specifying print format parameters

Options

Table 4-72. OUTPUT SHIFT parameter options and definitions

 

Option

Definition

 

 

 

 

 

 

 

v1

value 1.

 

 

An integer value in dots for the amount of shift on the simplex page or the odd

 

 

(front) side of the duplex page. (Each dot is 1/300 of an inch.)

 

 

The range for v1 is –75 to 75.

 

v2

value 2.

 

 

A value in dots for the amount of shift on the even (back) side of a duplex page.

 

 

The range for v2 is –75 to 75.

 

YES

Specifies that a shift occurs. A standard size shift occurs if YES is specified

 

 

(v1=75 and v2= –75).

 

NO

Specifies that no shift occurs (v1=0 and v2=0).

 

Default

 

NO

OUTPUT SHIFT

 

• If the origin of a print line is off the page, the printer prints as

parameter: points

 

much of the line as possible and provides a message, once

 

to note

 

per report, indicating that printing is off the page.

 

 

 

• Graphics and logos are not allowed to start off the page. If

 

 

 

they are positioned at a point that is outside the page

 

 

 

boundary, an error message is displayed.

 

 

 

OUTPUT SIZING

 

 

 

Specifies how the system matches the paper sizes in the output

 

 

 

bins and how it responds to paper and bin size mismatches.

 

 

 

When a stock has more than one tray assignment, and these

 

 

 

trays contain different size paper, the system tries to match the

 

 

 

paper sizes in the trays. You can specify one of the following

 

 

 

options based on whether or not the printer will be attended by

 

 

 

an operator during printing.

Syntax OUTPUT SIZING = {SEMIAUTO STOP BEST EXACT}

Using LCDS Print Description Language

4-79

Page 319
Image 319
Xerox FreeFlow manual Options 72. Output Shift parameter options and definitions