4 Command Line Interface

no banner configure mux

muxinfo - The circuit and PVC to which the switch is connected. (Maximum length: 32 characters)

Default Setting

None

Command Mode

Global Configuration

Command Usage

The user-entered data cannot contain spaces. The banner configure mux command interprets spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive non-letter characters is suggested for situations where whitespace is necessary for clarity.

Example

Console(config)#banner configure mux telco-8734212kx_PVC-1/23 Console(config)#

banner configure note

This command allows the administrator to configure the note information displayed in the banner. Use the no form to remove the note information from the banner display.

Syntax

banner configure note note-infono banner configure note

note-info- Miscellaneous information that does not fit the other banner categories, or any other information of importance to users of the switch CLI. (Maximum length: 150 characters)

Default Setting

None

Command Mode

Global Configuration

Command Usage

The user-entered data cannot contain spaces. The banner configure note command interprets spaces as data input boundaries. The use of underscores ( _ ) or other unobtrusive non-letter characters is suggested for situations where whitespace is necessary for clarity.

4-36

Page 332
Image 332
Accton Technology ES3528M-SFP manual Banner configure note, No banner configure mux