4 Command Line Interface

clock summer-time (date)

This command allows the user to manually configure the start, end, and offset times of summer-time (daylight savings time) for the switch on a one-time basis. Use the no form to disable summer-time.

Syntax

clock summer-timename date b-month b-day b-year b-hour b-minute e-month e-day e-year e-hour e-minute offset

no clock summer-time

name - Name of the time zone while summer-time is in effect, usually an acronym. (Range: 1-30 characters)

b-month - The month when summer-time will begin. (Options: january february march april may june july august september october november december)

b-day - The day summer-time will begin. (Options: sunday monday tuesday wednesday thursday friday saturday)

b-year-The year summer-time will begin.

b-hour- The hour summer-time will begin. (Range: 0-23 hours)

b-minute- The minute summer-time will begin. (Range: 0-59 minutes)

e-month - The month when summer-time will end. (Options: january february march april may june july august september october november december)

e-day - The day summer-time will end. (Options: sunday monday tuesday wednesday thursday friday saturday)

e-year-The year summer-time will end.

e-hour- The hour summer-time will end. (Range: 0-23 hours)

e-minute- The minute summer-time will end. (Range: 0-59 minutes)

offset - Summer-time offset from the regular time zone, in minutes. (Range: 0-99 minutes)

Default Setting

Disabled

Command Mode

Global Configuration

Command Usage

This command sets the summer-time time zone relative to the currently configured time zone. To display a time corresponding to your local time when summer-time is in effect, you must indicate the number of minutes your summer-time time zone deviates from your regular time zone.

4-74

Page 370
Image 370
Accton Technology ES3528M-SFP manual Clock summer-time date, No clock summer-time