Chapter 5: Reference

The Trigger Tab

• Wait for arm in

 

When the logic analyzer is armed by another instrument (as specified in

 

the Intermodule window), this trigger function becomes true when the

 

arm signal is received.

Wait for flag

 

Becomes true when the specified flag has the specified value. This trigger

 

function tests for a flag event.

OR Trigger

 

When the logic analyzer is armed by another instrument (as specified in

 

the Intermodule window), this trigger function becomes true when a

 

pattern occurs a specified number of times OR when the arm signal is

 

received.

• “Advanced Trigger Functions” on page 183

See Also

“To specify a label pattern event (Timing only)” on page 71

 

“To specify a label edge event” on page 72

 

“To break down a trigger function (timing or 200 Mb/s state only)” on

 

page 72

 

“To cross-trigger with another instrument” on page 112

General State Trigger Functions

When the state sampling mode's 200 Mb/s / 32M State configuration is selected, the following General State trigger functions are found in the Trigger Functions tab.

You can edit most of these trigger functions to specify particular pattern events or boolean combinations of events.

You can use the following types of events in these trigger functions: patterns, ranges, flags, counters, timers, and Wait for arm in (see “To cross-trigger with another instrument” on page 112).

You can use the following actions in these trigger functions: flags, counters, timers, store control, goto (for arbitrary sequencing), and trigger.

180

Page 180
Image 180
Agilent Technologies 16760A manual General State Trigger Functions, 180