Chapter 3: Using the Logic Analyzer in Timing or State Mode

Setting Up Triggers and Running Measurements

To give an event list a name

1.In the Trigger tab's Trigger Sequence area, select the If, If not, Else if, or Else if not button, and choose Name event list.

2.In the Name Event List dialog, enter the name and select the OK button.

To insert a named event

1.In the Trigger tab's Trigger Sequence area, select a label name button and choose to insert or replace a Named event.

2.In the Named Event selection dialog, select the named event, and select the OK button.

To edit a named event

1.In the Trigger tab's Trigger Sequence area, select the named event button and choose Edit locally or Edit globally.

Locally means to edit (and rename) this instance of the named event. Globally means to edit all instances of the named event.

2.In the Edit dialog, edit the event list as you would edit it in the Trigger tab's Trigger Sequence area.

Saving/Recalling Trigger Setups

You can save a trigger setup within a session by using trigger save/ recall.

“To save a trigger setup” on page 90

“To recall a trigger setup” on page 91

“To clear the trigger save/recall list” on page 91

See Also

“Save/Recall Subtab” on page 191

To save a trigger setup

1.Set up the trigger.

2.In the Trigger tab's Save/Recall subtab, select the Save button.

90

Page 90
Image 90
Agilent Technologies 16760A manual Saving/Recalling Trigger Setups, To save a trigger setup, To give an event list a name