Chapter 3: Using the Logic Analyzer in Timing or State Mode

Setting Up Triggers and Running Measurements

taken place).

If you only want to look the advanced trigger function, without editing it, you can expand the trigger function.

3. Select OK in the confirmation dialog.

To expand a trigger function

1.In the Trigger tab, select the number button of the trigger sequence level whose trigger function you want to expand.

2.Choose Expand function.

To compress a trigger function

Expanded trigger functions can be compressed back into their original form.

1.In the Trigger tab, select the number button of the trigger sequence level whose trigger function you want to compress.

2.Choose Compress function.

See Also

“Editing Advanced Trigger Functions (Timing or 200 Mb/s State Only)” on

 

page 83 for information on editing trigger functions that are broken down.

To create a trigger function library (timing or 200 Mb/s state only)

You can create your own libraries of trigger functions that are separate from logic analyzer configuration files (unlike saved/recalled trigger setups).

1. In the Trigger tab's Trigger Functions subtab, select the Trigger function libraries button.

2. In the Trigger function libraries dialog, select the Create button.

3. In the Create User Library dialog, enter the library name and description, and select OK.

4. In the Edit Trigger Function Library dialog, choose the Add function button.

5. In the Create User Function dialog, enter the function name and

73